Part Number: HBAA-40W-AG | Manufacturer: Power One Dc Power Supplies | NSN: 6130-01-193-6598 (6130011936598) | |
Item Name : Power Supply | CAGE Code: 54407 | FSC: 6130 Converters Electrical Nonrotating | |
Alternate P/N : HBAA40WAG | |||
2940 | 04-26-2024 |
We are pleased to inform you that part number HBAA-40W-AG is currently in stock. To receive a quote, please fill out the form below with all necessary information. This part number HBAA-40W-AG, with NSN 6130011936598, is manufactured by Power One Dc Power Supplies. We will respond to your quote request within just 15 minutes.
“*” Symbols for mandatory fields
An experienced and dedicated sale representative will contact you within 15 minutes with a quote. For any other questions related to Part HBAA-40W-AG, or to expedite your response, please feel free to call us at +1 (714) 705-4780, or email your Bill of Materials (BOM) to sales@veritableaviation.com. We are here to help 24/7, 365 days a year.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-193-6598 Item Description: Power Supply | 6130 | 011936598 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Hbaa-40w-Ag | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 10.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 3RD OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 100.0 AC POUNDS PER HOUR WET 4TH OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR WET 3RD OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR WET 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 240.0 AC POUNDS PER HOUR WET 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 6TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | -5.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 3RD OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 3RD OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 4TH OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 4TH OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+50.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 4TH POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 5TH POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 6TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 4TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 5TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | VOLTAGE ADJUSTMENT 6TH POWER OUTPUT |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL 5TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 800.0 DC MILLIAMPERES NOMINAL 6TH POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 4TH POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 5TH POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 6TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 5TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 6TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 4TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 5TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 6TH POWER OUTPUT |
Don’t forget That We Can Respond to Your Instant RFQ Within Fifteen Minutes. Simply Fill Out the Fields On This Website’S Front Page and Click “Request for Quote” and Our Account Managers Will Answer ASAP!
Request for Quote