Part Number: 25G010009-000 | Manufacturer: Hsi Electric Inc | NSN: 5930-01-056-1598 (5930010561598) | |
Item Name : Switch Flow | CAGE Code: 00U45 | FSC: 5930 Switches | |
Alternate P/N : 25G010009000 | |||
1541 | 04-26-2024 |
We are pleased to inform you that part number 25G010009-000 is currently in stock. To receive a quote, please fill out the form below with all necessary information. This part number 25G010009-000, with NSN 5930010561598, is manufactured by Hsi Electric Inc. We will respond to your quote request within just 15 minutes.
“*” Symbols for mandatory fields
An experienced and dedicated sale representative will contact you within 15 minutes with a quote. For any other questions related to Part 25G010009-000, or to expedite your response, please feel free to call us at +1 (714) 705-4780, or email your Bill of Materials (BOM) to sales@veritableaviation.com. We are here to help 24/7, 365 days a year.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-056-1598 Item Description: Switch Flow | 5930 | 010561598 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
25g010009-000 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.125 INCHES NOMINAL |
AWTN | OPERATING TEMP RATING | 85.0 DEG CELSIUS MAXIMUM AND 0.0 DEG CELSIUS MINIMUM |
AXGY | MOUNTING METHOD | FLANGE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE HOOK |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 400.00 ACTUATION POINT MINIMUM FEET PER MINUTE AND 399.00 DEACTUATION POINT NOMINAL FEET PER MINUTE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |